Driver on

SP Flash Tool + MediaTek MT65xx drivers download and installation guide including bricked devices –

MediaTek Chipset MT6589 MT6589M MT6589T

Instance of a MediaTek Chipset on a PCB

The next archive incorporates MTK interface drivers (32 & 64 bit) for Home windows XP, Home windows Vista, Home windows 7 & Home windows 8:

Obtain MTK Drivers (32 & 64 bit) XP Vista Win7 Win8
Microsoft Home windows 10 MTK Drivers (32 & 64 bit) + Drivers set up tutorial
Obtain SP Flash Device v3 & v5 – Newest variations

Let’s Put together our bricked MediaTek MT65xx machine for a brand new starting

This process apples to your  MT65xx machine if:

A. The MT65xx machine begins however hangs at producer brand or some other place.
B. The MT65xx machine restarts constantly after a particular variety of seconds.
C. You need to replace the MT65xx machine with one other firmware, or a particular firmware part like “restoration“.

1. Shut down your MT65xx machine and wait till it vibrates and all lights are off.
2. Take away the again cowl of the machine and take out the battery pack from the machine.

In the course of the interventions that I’ll describe on this web page, each time you join your MT65xx machine to your PC you have to to make it possible for it’s turned off, or, if it’s doable, it has the battery pack taken out. The procedures described beneath will work by placing your MT65xx machine in Obtain Mode, a state by which the Flash Reminiscence might be formatted and reprogrammed.

The flash reminiscence holds all of the binary data required for the MT65xx machine as well up and performance. (The flash reminiscence additionally incorporates the inner reminiscence of the machine, holding up drivers, purposes and different kinds of information in reminiscence buildings like ROM (Read Only Memory) & NVRAM (Non-Volatile Random Access Memory). The flash reminiscence of MT65xx gadgets with an unlocked boot loader might be reprogrammed in a method {that a} software program (SP Flash DeviceSmartPhone Flash Device for instance) can write information to it between particular factors (also referred to as reminiscence blocks). Instance: between 0x0 and 0x600000. These factors in reminiscence are contained in a file whose title consists of “scatter”, file which have to be loaded within the SP Flash Device. Based mostly on this file, the software program will then search for the required elements in the identical listing by which the “scatter” file resides, itemizing them afterwards.

If you cannot take away the battery from  your machine (if it’s a pill for instance) you solely have to shut down the machine in a standard method, or, if that’s not doable, do a pressured shut down by holding down the facility button for about 10 seconds, till all lights are off. (I do know that  my very own MediaTek 6589 machine – Acer Liquid E2 Duo Twin SIM, has a LED indicator close to the highest, however different gadgets for which this information may apply won’t have such an indicator).

3. Extract “MT65xx Drivers” folder from the archive.
4. Open up the System Supervisor window in your Home windows PC.
5. Join your machine to the PC through the USB cable maintaining a tally of the System Supervisor window.

The notification LED on the MT65xx machine (if there may be one) should gentle up in a deep blue colour as quickly as you join it to the PC. In case your machine was alive earlier than you eliminated the battery or shut it down (I imply not bricked), Within the System Supervisor window  the unknown machine “MT65xx Preloader” ought to present up.

Usually You’ve solely received about 5 seconds to right-click the unknown machine within the System Supervisor window after which to replace the motive force. After 5 seconds the MT65xx machine will routinely shut the communication interface and the “MT65xx Preloader” might be gone till subsequent time you join your MT65xx machine to the PC.

6. Proper-click the “MT65xx Preloader” from the System Supervisor window and click on “Replace driver software program”. Use the second choice to manually set up the motive force by indicating the motive force listing.
7. Browse to the extracted folder “MT65xx Drivers” and choose the folder akin to the model of Microsoft Home windows that you’re operating. Click on “Subsequent” and the motive force ought to now be putting in…

The MT65xx machine will preserve the communication interface alive longer (so long as required) if it detects a knowledge circulate from the PC (Instance: from SP Flash Device). That’s after all for those who received the driver named “MediaTek PreLoader USB VCOM Port (COMx)  put in and exhibiting up below “Ports (COM & LPT) within the System Supervisor window, as quickly as you join your machine to the PC. This additionally signifies that the machine driver that you’ve got put in at Step 7 was appropriately acknowledged. In regular circumstances, with the battery pack inside, the Built-in Circuit inside the MT65xx machine will start to cost the battery after 5 seconds.

What if our MT65xx machine has received the incorrect preloader? Right here we go…

For the file, I will think about the MT65xx machine as being recoverable via this process in that case by which there nonetheless is an interplay with the System Supervisor on the Home windows PC whenever you join the MT65xx machine with out the battery pack if doable, through USB and the blue gentle turns ON (if the notification LED exists).

This process apples to your MT65xx machine if:

A. The MT65xx machine isn’t beginning in any respect.
B. The MT65xx machine is beginning/restarting (vibrates) however the display screen stays black.
C. The SP Flash Device experiences an error that forestalls the profitable obtain of the firmware recordsdata to your MT65xx machine as a result of your “PRELOADER” firmware part that you’re making an attempt to obtain is dangerous or corrupt.

BROM ERROR : S_FT_ENABLE_DRAM_FAIL (4032)

SP Flash Device Error: BROM ERROR : S_FT_ENABLE_DRAM_FAIL (4032)

A, B and C are instances by which most probably you beforehand downloaded a foul or corrupt “PRELOADER” firmware part to your MT65xx machine through SP Flash Device. To get the fitting thought you may need to learn beneath:

There may be the scenario by which for those who obtain a brand new firmware to your MT65xx machine that has both a foul, incompatible or corrupt “PRELOADER” part. The SP Flash Device will report the obtain as being profitable however your MT65xx machine won’t begin afterwards and neither will the SP Flash Device be capable of obtain the firmware elements once more as a result of the traditional “MediaTek PreLoader” communication interface won’t begin until the SP Flash Device will first ship a superb “PRELOADER” firmware part.

The “PRELOADER” firmware part has the required attributes to permit the MT65xx machine to speak with the PC trough the traditional “MediaTek PreLoader” obtain interface, trough which the SP Flash Device is succesful to ship the remainder of the firmware elements to the  Flash Reminiscence of the MT65xx machine. If this “PRELOADER” firmware part was beforehand downloaded to the Flash Reminiscence of the MT65xx machine nevertheless it was incorrect or corrupt, the MT65xx machine will use a particular, low-layer interface, to speak with the PC. This interface is non-removable and is the one interface that permit us to vary the “PRELOADER”  firmware part if meant.

The SP Flash Device can even deal with this low-layer interface. Nonetheless, the SP Flash Device can solely use this low-layer obtain interface to switch the “PRELOADER” part of the firmware. Afterwards, with the proper “PRELOADER” firmware part, the MT65xx machine will immediately reinitialize its associated Built-in Circuits, switching to the traditional “MediaTek PreLoader” obtain interface that can absorb the remainder of the firmware elements despatched by SP Flash Device. Your machine will NOT stay lifeless for those who observe this trough.

This low-layer interface is there to save lots of the machine no-matter how worst it received bricked. You solely want the fitting driver to begin the restoration means of the Flash Reminiscence. The correct driver for this low-layer obtain interface can also be situated in “MT65xx Drivers” folder. The MT65xx machine will preserve the low-layer obtain interface alive for about one minute. Throughout this time it’s worthwhile to replace or set up the motive force.

On this case, initially, the PC may present an “Unknown Device” in System Supervisor window, then it’d routinely set up a driver from Home windows Replace, most probably THE WRONG DRIVER. If so, you need to then manually force-update the motive force for the low-layer obtain interface of the MT65xx machine.

In my case, Microsoft Home windows 7 64 bit wrongly put in the low-layer obtain interface of my MT65xx machine as a “Alcatel Single RNDIS Interface” below “Community adapters“. The machine is usually with an exclamation mark and it disconnects frequently being unable to begin. That was as a result of my PC was set to routinely seek for drivers at Home windows Replace for all the brand new linked gadgets, so I anticipated this to occur. A easy methodology to keep away from this situation is to disconnect the PC from the web earlier than connecting the MT65xx machine to that PC through USB. In any other case you might need a tough time discovering the machine within the System Supervisor window. relying upon the precise mannequin of your MT65xx machine and the working system in your PC.

But when the dangerous has occurred I needed to right-click the suspicious machine, choose “Replace driver software program“, then browse the extracted “MT65xx Drivers” folder. In my case, by which a incorrect driver was already put in for the low-layer obtain interface of my MT65xx machine, I needed to choose the second choice, to manually browse for the motive force (Choose it from a listing from my pc) in order that I can force-replace the incorrect driver discovered routinely by Home windows Replace. So you need to do if that is so. Additionally you may choose “Present all gadgets” from the machine sort choice window.

I clicked “Have Disk…” and browse to the “MT65xx Drivers” folder the place I opened the one akin to my working system, chosen MDMCPQ.INF and hit “Open” then “OK“. Within the window “MTK USB Port” was now proven as being put in, which is the proper low-layer obtain interface driver that I wished to have.

On 64 bit working techniques you may want to substantiate the unsigned driver set up and you may additionally do some settings with a view to to permit your 64 bit working system to make use of unsigned drivers like those offered on this web page. My expertise with these drivers on Microsoft Home windows 7 64 bit was OK.

The purpose is that, whenever you join the machine with no battery inside or turned off and the blue gentle comes on, within the System Supervisor Window you need to have certainly one of this two gadgets exhibiting up below “Ports (COM & LPT)“:

1. The low-layer obtain interface – driver title: MTK USB Port (COMx)
2. The MediaTek PreLoader obtain interface – driver title: MediaTek PreLoader USB VCOM Port (COMx)

If in case you have that, you may proceed downloading the proper  firmware in your MT65xx machine unsing SP Flash Device. If you recuperate your MT65xx machine from the state by which it has the incorrect preloader, you need to have each drivers talked about above prepared to determine the obtain hyperlink together with your MT65xx machine. You possibly can have a look at the information on the high aspect of this text to see how the MT65xx machine behaves when it has the proper preloader.

If in case you have bother putting in a brand new MTK driver in your system otherwise you see a excessive or uncommon quantity beside COM Ports displayed within the System Supervisor, you may need to clear the USB driver rubbish in your system with USBDeview – Obtain USBDeview for 32 & 64 bit Home windows – be taught what it does and learn how to eliminate undesirable USB drivers and COM Port duplicates.